Device Parameters Reference
Selecting Device under "Signals to Plot" lets you inspect an internal NGSpice operating-point or small-signal parameter for any single device instance in your schematic — without writing .save @device[param] by hand.
How the selector works
The dropdown (Select device param (1)) builds a path of the form:
<SubcircuitInstance> ▸ <DeviceInstance>[<parameter>]
For example, in the screenshot from the previous page:
OpampSS_0 ▸ M0[gm]
This corresponds to the NGSpice directive:
.save @m.OpampSS_0.M0[gm]
which tells NGSpice to record the small-signal transconductance (gm) of transistor M0 inside the subcircuit instance OpampSS_0.
Commonly available MOSFET parameters
| Parameter | Meaning |
|---|---|
gm | Small-signal transconductance |
gds | Drain-source small-signal conductance |
vgs | Gate-source voltage |
vds | Drain-source voltage |
vth | Threshold voltage |
id | Drain current |
cgs, cgd | Gate-source / gate-drain capacitance |
The exact parameter list shown in the dropdown depends on the device model used in the selected component (e.g. SKY130 PDK models will expose the model's specific parameter set).
Adding multiple device parameters
Click Select device param (1) again to add a second tracked device parameter — each one becomes a separate trace in the Waveform Editor, labeled by its full path (e.g. OpampSS_0.M0[gm]).